IEC/BS Standard 19-33kV-XLPE Insulated MV Middle Voltage Power Cable
Application
Suitable for energy networks such as power plants,distribution system etc. It usually used for installation in ducts, underground and outdoors.
Due to its robustness and high electrical stability, medium voltage cables are used in harsh environments.
Note: The Red outer sheath can be prone to fading when exposed to UV rays.
Standards
Flame propagation to BS EN60332BS6622IEC 60502
Cable Construction
Conductor: stranded plain annealed circular compacted copper conductors or aluminium conductor
Insulation: cross link polyethylene (XLPE)
Metallic Screen: individual or overall copper tape screen
Separator: copper tape with 10% overlap
Bedding: polyvinyl chloride (PVC)
Armoured: Steel Wire Armour (SWA), Steel Tape Armour (STA), Aluminium Wire Armour (AWA), Aluminium Tape Armour (ATA)
Sheath: PVC/PE outer sheath
Sheath colour: Red or Black
Electrical data
Conductor max operating temperature: 90°C
Screen max operating temperature: 80°C
Conductor max temperature during S.C: 250°C
Laying conditions at trefoil formation
Soil thermal resistivity |
120˚C. Cm/Watt |
Burial depth |
0.5m |
Ground temperature |
15°C |
Air temperature |
25°C |
Frequency |
50Hz |
Data Sheet
19/33kV Single core copper conductor XLPE insulated copper tape screened aluminium wire armoured pvc/pe sheathed cables
Nominal area of conductor |
Maximum conductor resistance at 20 ℃ |
Thickness of xlpe insulation |
Thickness of copper tape |
Thickness of extruded bedding |
Dia. of armoured wire |
Thickness of outer sheath |
Approx. Overall diameter |
Approx. Cable weight |
mm2 |
Ω/km |
mm |
mm |
mm |
mm |
mm |
kg/km |
|
50 |
0.387 |
8 |
0.075 |
1.2 |
2 |
2.2 |
39.4 |
2050 |
70 |
0.268 |
8 |
0.075 |
1.2 |
2 |
2.2 |
41 |
2330 |
95 |
0.193 |
8 |
0.075 |
1.2 |
2 |
2.3 |
43.1 |
2710 |
120 |
0.153 |
8 |
0.075 |
1.2 |
2 |
2.3 |
44.6 |
3020 |
150 |
0.124 |
8 |
0.075 |
1.3 |
2.5 |
2.4 |
47.4 |
3570 |
185 |
0.0991 |
8 |
0.075 |
1.3 |
2.5 |
2.5 |
49.2 |
3990 |
240 |
0.0754 |
8 |
0.075 |
1.3 |
2.5 |
2.5 |
51.7 |
4670 |
300 |
0.0601 |
8 |
0.075 |
1.4 |
2.5 |
2.6 |
54.1 |
5410 |
400 |
0.047 |
8 |
0.075 |
1.4 |
2.5 |
2.7 |
57.2 |
6430 |
500 |
0.0366 |
8 |
0.075 |
1.5 |
2.5 |
2.8 |
60.6 |
7620 |
630 |
0.0283 |
8 |
0.075 |
1.6 |
2.5 |
2.9 |
64.8 |
8935 |
19/33kV Three cores copper conductor XLPE insulated copper tape screened galvanized steel wire armoured pvc/pe sheathed cables
Nominal area of conductor |
Maximum conductor resistance at 20 ℃ |
Thickness of xlpe insulation |
Thickness of copper tape |
Thickness of extruded bedding |
Dia of armoured wire |
Thickness of outer sheath |
Approx. Overall diameter |
Approx. Cable weight |
mm2 |
Ohm/km |
mm |
mm |
mm |
mm |
mm |
kg/km |
|
50 |
0.387 |
8 |
0.075 |
1.8 |
3.15 |
3.4 |
78.8 |
9230 |
70 |
0.268 |
8 |
0.075 |
1.8 |
3.15 |
3.5 |
82.5 |
10310 |
95 |
0.193 |
8 |
0.075 |
1.9 |
3.15 |
3.6 |
87 |
11640 |
120 |
0.153 |
8 |
0.075 |
2 |
3.15 |
3.7 |
90.6 |
12850 |
150 |
0.124 |
8 |
0.075 |
2 |
3.15 |
3.8 |
93.8 |
14150 |
185 |
0.0991 |
8 |
0.075 |
2.1 |
3.15 |
4 |
97.9 |
15700 |
240 |
0.0754 |
8 |
0.075 |
2.2 |
3.15 |
4.1 |
104 |
18120 |
300 |
0.0601 |
8 |
0.075 |
2.3 |
3.15 |
4.3 |
109 |
20570 |