60227 IEC 52 RVV 300/300V Flexible Building Wire Light PVC Insulated PVC Sheath

Light PVC Insulated PVC Sheath RVV Flexible Building Wire for Internal Wiring.

    Application

    Used in electronics, instruments and electronic equipment and automatic generation device with the power cord, line and signal transmission lines, concrete can be used for anti-theft alarm system, building talkback system, instrument and meter, and monitoring control such as the installation of surveillance.

    Technical Performance

    Rated Voltage (Uo/U)

    450/750V

    Conductor temperature

    Maximum conductor temperature in normal use: 70ºC

    Installation temperature

    Ambient temperature under installation shall not be below 0ºC

    Continuos operating temperature

     ≤70℃ for standard products, 90℃ or 105℃ for customized products.

    Shelf Life

     30 years

    The smallest bending radius is six times the diameter of cable

    Unless specially agreed otherwise, instillation colors are in accordance with BS 6004 specification as follows

    Single Core

     Red, Black, Yellow, Blue, Green / Yellow

    Two Core

     Red and Black

    Minimum bending radius

    The bending radius of cable: (D-Diameter of cable)

    D≤25mm------------------≥4D

    D>25mm------------------≥6D

    Constructions

    Conductor: Number of conductors: 2,3 or other multi-core.

    The conductors shall comply with the requirement given in IEC 60228 for class 5.

    Assembly of cores:

    Circular cord: the cores shall be twisted together.

    Flat cord: the cores shall be laid parallel.

    Insulation: PVC(Polyvinyl Chloride) Type PVC/D according to IEC

    Sheath: PVC(Polyvinyl Chloride) Type PVC/ST5 according to IEC

    Specifications

    60227 IEC 52 Standard

    Data Sheet

    Nominal Cross Sectional Area of Conductor

    Class of conductor

    Nominal Insulation Thickness

    Nominal Sheath Thickness

    Max.Overall Diameter

    Max.D.C.Resistance at 20 ℃ (Ω/km)

    Min.Insulation Resistance at 70 ℃

    (mm2)

    /

    (mm)

    (mm)

    (mm)

    Plain

    Metal-coated

    (Ω/km)

    2x0.5

    5

    0.5

    0.6

    5.9

    39

    39

    0.012

    2x0.5

    5

    0.5

    0.6

    3.7x5.9

    24

    39

    0.012

    2x0.75

    5

    0.5

    0.6

    6.3

    46

    26

    0.01

    2x0.75

    5

    0.5

    0.6

    3.8x6.3

    31

    26

    0.01

    3x0.5

    5

    0.5

    0.6

    6.3

    49

    19.5

    0.012

    3x0.75

    5

    0.5

    0.6

    6.7

    60

    19.5

    0.01